WORKING PRINCIPLE
SBX RF-Capacitance/ Admittance Level Switch, Solid Level Switch, Bulk solids handling (Food Grade)
RF-Capacitance /Admittance level switch consists of a guard section, upper insulation, main probe and grounding. The guard section is designed to overcome possible medium attachment and to secure signal accuracy. The special structure is suitable for detecting different mediums without being affected by attachments. The upper main probe, guard, and grounding are all insulated. The level of the medium can be detected by the increasing of admittance when medium reaches the main probe. The grounding and the main probe are insulated, thus the device will still function accurately and not cause false alarms when the medium attaches the probe.
FEATURE
。Time delay function from 0-30 seconds
。IP65 housing protection
。5 A/250Vac output DPDT
。High/low failsafe
。Alarm testing
。Explosion Proof model available
。Anti-Viscosity
。Easy Installation
。Stable; Not affected by temperatureerature
。Highest temperatureerature tolerance of 550°C
。Explosion-proof 450°C
。Applicable in liquid, syrup, solid, powder,and surface level detection